86exporter.com Home       Products Catalog      Suppliers Catalog      Log In        Sign up
      About Us
      Profile
      Products
      Contact Us


Nanjing Conpo Power Tech. Co., Ltd

Products >> On-Line UPS

On-Line UPS

Build Your Online Product Catalogs?



Description
Product Name: On-Line UPS
Supply Ability:
Related proudcts ups,
Specifications C1K/2K/3K, C1KS/2KS/3KS
Price Term: FOB,CFR,CIF
Port of loading:
Minimum Order
Unit Price:

Feature:
1. True on-line double conversion technology with advantage microprocessor control
2. Wide input voltage range
3. Zero transfer time
4. Prottection against all type of power problems
5. Self test while start of the UPS
6. Site wiring fault warning
7. On-battery power-on function
8. Smart RS232 communication interface
9. Intelligent slot available
10. Sealed lead-acid, maintenance free battery
Application:
Servers, Data-center, Critical network devices, Sensitive electric equipment, Telecom.

Model C1K C2K C3K C1KS C2KS C3KS
Capacity VA/W 1KVA/0.7KW 2KVA/1.4KW 3KVA/2.1KW 1KVA/0.7KW 2KVA/1.4KW 3KVA/2.1KW
Input Nominal voltage 110/115/120VAC or 220/230/240VAC
Voltage range 180~300VAC
Frequency range 50Hz: 46~54Hz; 60Hz: 56~64Hz
Phase Single phase
Power factor > 97%
Connection IEC320-10A IEC320-10A IEC320-16A IEC320-10A IEC320-10A IEC320-16A
Output Voltage 110/115/120VAC x(1+/-2%) or 220/230/240VAC x(1+/-2%)
Frequency Synchronization range(line mode); 50 or 60 x(1+/-0.2%)Hz (Battery mode)
Phase Single phase
Wave form Sine wave
Power factor 0.7
Voltage distortion 3% 4% 4% 3% 4% 4%
Overload capability 110%-150% for 30sec. 150% for 200ms
Current crest ratio 3: 1
Connections IEC320*4 IEC320*6 IEC320*3 IEC320*4 IEC320*6 IEC320*3
Battery Type Sealed, maintenance free, lead-acid
Nominal
DC voltage 36VDC 96VDC 96VDC
Quantity 3pcs 8pcs 8pcs Depends on the requested back-up time
Back-up time(full load) 5min 9min 5min Depends on the capacity of the external battery bank
Recharge time 5hrs to 90% if capacity Depends on the capacity of the external battery bank
Automatic transfer On overload and UPS failure
Before UPS
power on Default " ON' user adjustable to ' YES"
Voltage range 40~132VAC(default), user adjustable within 40~143VAC or 80~264VA(default), user adjustable within 80~286VAC
Transfer time AC to DC
zero Inverter to bypass 4ms(typical)
Indicator LED display Load level/Battery level, Battery, Utility power, Inverter, Bypass, Overload,

Contact Us
Company: Nanjing Conpo Power Tech. Co., Ltd
Contact: Mr. France M.
Address: No.1,Binjiang Avenue,Hi-tech.Development zone,Pukou District,Nanjing City,Jiangsu Province,P.R China
Postcode: 210031
Tel: 0086 25 58895618
Fax: 0086 25 58895718
E-mail:         


Copyright© Nanjing Conpo Power Tech. Co., Ltd All Rights Reserved.
Tel : 0086 25 58895618 Fax : 0086 25 58895718